COMMERCIAL 80 SERIES GRAIN DRYERS
Capacities from 2,300 to 2,925 bushels/hour
MODELS |
2680 |
3180 |
| DIMENSIONS |
|
|
| Length |
35'-3" |
35'-3" |
| Height |
41'-6" |
49'-6" |
| Width |
8'-4" |
8'-4" |
Width, including Platforms
|
14' |
14' |
| Grain Column Width |
12" |
12" |
| Grain Column Length |
24' |
24' |
| |
|
|
| WEIGHT, EMPTY (lbs.) |
36,300 |
43,300 |
| |
|
|
| MOTOR SIZES (H.P.) |
|
|
| Heat Fans |
(3) 30 |
(4) 30 |
| Cool or Heat Fans |
(2) 20 |
(2) 20 |
| Level Auger |
10 |
10 |
| Discharge Auger |
3 |
3 |
| SCR Drive |
1/3 |
1/3 |
| |
|
|
| TOTAL RUNNING AMPS |
|
|
| 208 Volts - 3 phase |
412 |
492 |
| 230 Volts - 3 phase |
374 |
446 |
| 460 Volts - 3 phase |
187 |
223 |
| 575 Volts - 3 phase |
150 |
178 |
| |
|
|
| BURNER CAPACITIES (BTUs) |
|
|
| Normal Operating, Dry & Cool |
14,319,525 |
19,092,700 |
| Normal Operating, All Heat |
22,080,025 |
26,853,200 |
| Maximum |
30,136,260 |
36,561,360 |
| |
|
| DRYING CAPACITIES (bushels/hour) * |
|
|
| Shelled Corn (Dry & Cool) 20% -15% |
2,300 |
2,925 |
| Shelled Corn (Dry & Cool) 25% -15% |
1,350 |
1,750 |
| Wheat, Oats (Dry & Cool) 17% -12% |
2,190 |
2,735 |
| Grain Sorghum (Dry & Cool) 20% -15% |
2,200 |
2,750 |
| Soybeans, Barley (Dry & Cool) 18% -13% |
1,640 |
2,050 |
| Sunflowers (Dry & Cool) 17% -10% |
2,190 |
2,735 |
| |
|
|
| TOTAL HOLDING CAPACITIES (bushels) |
1,629 |
1,953 |
|
 |
 |